bassix.blogg.se

Rheocalc software
Rheocalc software








rheocalc software rheocalc software
  1. #Rheocalc software manual#
  2. #Rheocalc software Pc#

#Rheocalc software Pc#

Measure viscosity at multiple speeds automaticallyĪllows installation of multiple TESC Systems in a relatively small benchtop area for redundancy and greater testing versatilityĭedicated PC is not required for standard instrument operation*Ĭonfigured for use with the Brookfield® DV2T viscometer and compatible with most Brookfield® models Pre-developed test programs for common lubricants (gear oil and ATF) Reduces result variability due to temperature fluctuation Provides an automated alternative to ASTM D2983 sample conditioning and testingĮliminates sample disruption during preheating, room temperature stabilization, cooling and final viscosity testing Other fluids where low-temperature viscosity is criticalįully integrated and automated thermal conditioning and testing (−40 ☌ to +90 ☌) Reduces result variability due to temperature fluctuation. Eliminates sample disruption during preheating, room temperature stabilization, cooling and final viscosity testing. Environmentally-friendly Peltier thermoelectric cooling does not require hazardous fluids. The compact, economical TESC-2983 (thermoelectric sample conditioner) viscometer system provides outstanding precision for the new ASTM D2983 automated procedure D conditioning and testing process for low temperature viscosity of gear oils and ATF, as well as ASTM D8210. The easy-lift system of the TESC simplifies positioning of the viscometer head.įor Low Temperature Viscosity of LubricantsAutomated The unit also measures and records viscosity at multiple speeds automatically. The TESC-2983 has pre-programmed test protocols for common lubricants (gear oil and automatic transmission fluids) which reduces instrument set-up time. The enclosed insulated sample chamber mitigates the effects of laboratory air temperature on the test. The Peltier solid-state cooling is environmentally friendly and does not require the use of hazardous CFC refrigerants or flammable bath fluids. Its small footprint conserves bench space and allows installation of multiple TESC systems providing redundancy and multiple temperature cycles. The TESC-2983 is a cost effective, ultra-compact design with low energy consumption (only 300 W power). The system offers limited operator intervention compared to the other labor-intensive procedures.

#Rheocalc software manual#

The TESC-2983 is a fully-integrated thermoelectrically heated-cooled sample conditioner and rotational viscometer system that offers vastly improved precision (nearly 2 times better) with Procedure D over the other manual D2983 procedures. ASTM Approves A New Automated Procedure D for D2983










Rheocalc software